Circuit Breakers HITACHI

HITACHI CIRCUIT BREAKERS
* New Line-ups With Fully Integrated Configuration,
Advanced Performance And Simplified Operation

* Reduced Total Costs Through Increased Efficiency in Specification Changes and Replacement

 

Flexibility
Integrated Models
Almost models use electronic variable adjustment of rated current and internally loaded accessories. Easily accommodate specification changes and reduce stock control cost.

Compatibility

Unified Dimensions
Dimensions are unified for economical models and standard models *1, interrupt capacity is unified *2, for the fuse-free breaker and earth leakage breaker to facilitate easy replacement.
* 1 400, 600AF
* 2 Within the frame for the same rated current

Capability
Improvement of Breaking Performance
Performance of short-circuit breaking has been developed for the requirement of IEC standard and we have just
realized the performance lcs=lcu (lcs=100% lcu)

Certification of EMC Performance by Third Party
VDE in Germany has certificated HITACHI New Pair breakers regarding EMC (electromagnetic compatibility) requirements of IEC standard, and the high performance of them has been proved. (In addition, applying to Singapore PSB certification)
EMC Test Item of IEC 60947-2 Standard Requirements

Harmonic current
Current dips
Electrostatic discharges (IEC61000-4-2)
Radiated electromagnetic fields (IEC61000-4-3)
Electrical fast transient/burst (IEC61000-4-4)
Surges (IEC61000-4-5)
And other


Ecology
Positive Adoption of Plastic Material Suitable for Recycling!
We indicate material name of main parts on them for easy to recycling.

 

Features
1. Specification Change is Quickly Performed by Variable Adjustment of Rated Current and Cassette-Housed interior Accessory
Model types are entirely integrated with the rated current setting system by single switch operation. Specifications easily, quickly changed using interior accessory unit cassettes (AL, AUS, SHT….FFB only) Model type integration and cassette packaging enable ordering prior to detailed specification decision as well as reducing stock control and arrangement procedures, contributing to improved management efficiency.

Use Installable Cassette

The cassette including the alarm switch (AL), auxiliary switch (AUX), and shunt trip (SHT….FFB) can be installed by the user, quickly responding to specification change.For the frames with rated current of 400A or more, the cassette is provided with a terminal block (6-pole) as standard. It is not necessary to prepare and external terminal block. (Incase of over 6 pole) internal a terminal block is not available.


2. Dimensions are unified* for the economical and standard types, contributing to total cost reduction of the control panel.

*Up to type 600AF

Even height is unified in addition to the conventional projected area unification. This compatibility reduces the total cost in mounting panels. Interrupting capacity is also unified for the fuse-free breaker and earth leakage breaker within the frame of the same rated current, enabling easy, smooth replacement.


3. A Lot of Advanced Technologies will enable High Reliance
Excellent Current Limiting Function.

Owing to high-speed current interruption, excellent current limiting is achievable. Thus breakers stress with respect to temperature or mechanic is Reduced, circuits are securely protected.

Higher MT current Reduces Miss trip by motors rush Current.

Instantaneous tripping current is now greater than conventional models. Reduces probability of miss trip at high inrush current. Improvement of the voltage equilibrium characteristic of the earth leakage breaker.

Double Instantaneous Trip

Double electronic and mechanical instantaneous tripping characteristic protects equipments from short circuit.

Easy Coordination
Tripping characteristics include agustable long time delay & short time delay in propotion to long time delay (setting current x 1,000 %) are contribute to easier coordination with other electric appliance such as down stream circuit breakers, transformers and wires

HITACHI FUSE FREE BREAKER
Hitachi Fuse Free Breakers are produced in the variety of types shown below. Any type can be freely chosen according to the purposes of applications and circuit conditions, making it possible to design an electric circuit with high economy and reliability.

Improvement of short-circuit breaking performance (lcs=lcu)
One of these requirements is rated service short circuit breaking capacity (lcs) and it requires verifying conductivity after short-circuit breaking. The performance of short-circuit breaking of our breakers has been developed for the requirement and we have just realized the performance lcs=lcu (lcu :rated ultimate short-circuit breaking capacity) We have just acquired world-wide level of the performance.

 

 


น้ำหนัก : 1 กรัม